You can have your drill press converted to 230 volt
operation.
A qualified electrician must perform this conversion. Should
you desire to have your drill press converted for 230 volt
operation, take your drill press to your local Authorized
Delta Service Center. You can call 800-223-7278 for the
location of the nearest Authorized Service Center.
When converted for 230 volt operation, your drill press is
intended for use on a circuit that has an outlet like the one
illustrated in Fig. C. After conversion to 230 volts, the drill
press will have a grounding plug that looks like the plug
illustrated in Fig. C.
Make sure the drill press is connected to an outlet having
the same configuration as the plug. No adapter is available
or should be used when the drill press is converted for 230
volts. If the drill press must be reconnected for use on a
different type of electrical circuit, the re-connection should
be made by qualified service personnel; and after re-
connection, the tool should comply with all local codes and
ordinances.
7
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
EXTENSION CORDS
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension
cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using
an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a
drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending
on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Fig. D-1
Fig. D-2
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 120
up to
25 18 AWG
0-6 120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120
up to
25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120
up to
25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120
up to
25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 240
up to
50 18 AWG
0-6 240 50-100 16 AWG
0-6 240 100-200 16 AWG
0-6 240 200-300 14 AWG
6-10 240
up to
50 18 AWG
6-10 240 50-100 16 AWG
6-10 240 100-200 14 AWG
6-10 240 200-300 12 AWG
10-12 240
up to
50 16 AWG
10-12 240 50-100 16 AWG
10-12 240 100-200 14 AWG
10-12 240 200-300 12 AWG
12-16 240
up to
50 14 AWG
12-16 240 50-100 12 AWG
12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
Fig. C
3. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating
between 150 - 250 volts, inclusive: