Delta Qumi_DP274-A13VVxx Service Manual Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 71
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
Delta Elec. Inc. Qumi Ver.02
Company Confidential Vivitek ______________________ Delta____________
49
2011/07/05
6-2. Calibrate Analog YUV
Equipment: VG828, must be take off H/V sync terminal from machine.
Step 1 In Service Mode select ADC Calibration - YUV. In this menu input pattern with 75SMPTE
pattern for calibrate YUV Source and notice that the input source must be 480i format
After input ready press “Enter”key to proceed
Input Pattern
Step 2 : After complete the OSD will show the picture as follow, if not complete, just close the OSD
NOTE:
You can select Calibration Status – VGA or Calibration Status – YUV item to watch the
calibrated value at any time