3. Instruction Set
3-373
D1232 Output pulse number for ramp-down stop when Y0 masking sensor receives
signals. (LOW WORD)
D1233 Output pulse number for ramp-down stop when Y0 masking sensor receives
signals. (HIGH WORD).
D1234 Output pulse number for ramp-down stop when Y2 masking sensor receives
signals (LOW WORD).
D1235 Output pulse number for ramp-down stop when Y2 masking sensor receives
signals (HIGH WORD).
D1026 Pulse number for masking Y0 when M1156 = ON (Low word)
D1027 Pulse number for masking Y0 when M1156 = ON (High word)
D1135 Pulse number for masking Y2 when M1158 = ON (Low word)
D1136 Pulse number for masking Y2 when M1158 = ON (High word)