Delta DVP-ES2 User Manual Page 542

  • Download
  • Add to my manuals
  • Print
  • Page
    / 702
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 541
DVP-ES2/EX2/SS2/SA2/SX2 Operation Manual - Programming
3-426
M0
RST
= D0 K1
DPPMR D200
D202 K100000
Y0
= D0 K2
DPPMR D204
D206 K100000
Y0
= D0 K3
DPPMR D208
D210 K100000
Y0
= D0 K4
DPPMR D212
D214 K100000
Y0
MOV D0
M0
INCP
END
M1029
D0
M1029
K1
3. Operation:
When PLC runs and M0 = ON, PLC will start the first point-to-point motion by 100KHz. D0 will
plus 1 whenever a point-to-point motion is completed and the second point-to-point motion will
start to execute automatically. The operation pattern repeats until the fourth point-to-point
motion is completed.
Points to note:
Associated flags and registers:
M1029: CH0 (Y0, Y1) pulse output execution completed
D1030: Present number of Y0 output pulses (HIGH WORD).
D1031: Present number of Y1 output pulses (LOW WORD).
D1336: Present value of Y2 pulse output. D1336 (High word)
D1337: Present value of Y2 pulse output. D1337(Low word)
D1340:
Start/end frequency of pulse output CH0 (Y0), CH1(Y2) for DPPMR/DPPMA
instruction
D1343:
Ramp up/down time of pulse output CH0 (Y0), CH1(Y2) for DPPMR/DPPMA
instruction
Page view 541
1 2 ... 537 538 539 540 541 542 543 544 545 546 547 ... 701 702

Comments to this Manuals

No comments