DVP-ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming
2-40
Special
D
Content
ES2
EX2
SS
2
SA
2
SX
2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
D1023*
Register for Storing detected pulse width (unit:
0.1ms)
0 - - R/W NO 0
D1025*
Code for communication request error
0 - - R NO 0
D1026*
Pulse number for masking Y0 when M1156 = ON
(Low word)
0 0 - R/W NO 0
D1027*
Pulse number for masking Y0 when M1156 = ON
(High word)
0 0 - R/W NO 0
D1028
Index register E0
0 - - R/W NO 0
D1029
Index register F0
0 - - R/W NO 0
D1030
PV of Y0 pulse output (Low word)
- - - R/W YES 0
D1031
PV of Y0 pulse output (High word)
- - - R/W YES 0
D1032
PV of Y1 pulse output (Low word)
0 - - R/W NO 0
D1033
PV of Y1 pulse output (High word)
0 - - R/W NO 0
D1036*
COM1 (RS-232) communication protocol
H’86 - - R/W NO H’86
D1037*
Register for setting 8-sets SPD function (has to be
used with M1037)
0 - - R/W NO 0
D1038
1. Delay time setting for data response when PLC
is SLAVE in COM2 / COM3 RS-485
communication. Range: 0 ~ 10,000 (unit: 0.1ms).
2. By using PLC LINK in COM2 (RS-485), D1038
can be set to send next communication data with
delay. Range: 0 ~ 10,000 (Unit: one scan cycle)
- - - R/W NO 0
D1039*
Fixed scan time (ms)
0 - - R/W NO 0
D1040
No. of the 1st step point which is ON.
0 - - R NO 0
D1041
No. of the 2nd step point which is ON
0 - - R NO 0
D1042
No. of the 3rd step point which is ON.
0 - - R NO 0
D1043
No. of the 4th step point which is ON
0 - - R NO 0
D1044
No. of the 5th step point which is ON.
0 - - R NO 0
D1045
No. of the 6th step point which is ON
0 - - R NO 0
D1046
No. of the 7th step point which is ON.
0 - - R NO 0
D1047
No. of the 8th step point which is ON
0 - - R NO 0
D1049
No. of alarm which is ON
0 - - R NO 0
D1050
D1055
Converted data for Modbus communication data
processing. PLC automatically converts the ASCII
data in D1070~D1085 into Hex data and stores
the 16-bit Hex data into D1050~D1055
0 - - R NO 0
D1062*
Average number of times an analog signal is input
to the EX2/SX2 series PLC
The default value is K10 for EX2 version 2.6 and
version 2.8.
2 - - R/W YES 2
D1067*
Error code for program execution error
0 0 - R NO 0
D1068*
Address of program execution error
0 - - R NO 0