Delta DVP-ES2 User Manual Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 702
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
DVP-ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming
2-44
Special
D
Content
ES2
EX2
SS
2
SA
2
SX
2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
D1253
COM3 (RS-485) communication error code (only
applicable for MODRW/RS instruction)
0 - - R/W
NO
0
D1255*
COM3 (RS-485) PLC communication address
50 - - R/W
YES
1
D1256
D1295
For COM2 RS-485 MODRW instruction.
D1256~D1295 store the sent data of MODRW
instruction. When MODRW instruction sends out
data, the data will be stored in D1256~D1295.
Users can check the sent data in these registers.
0 - - R NO 0
D1296
D1311
For COM2 RS-485 MODRW instruction.
D1296~D1311 store the converted hex data from
D1070 ~ D1085 (ASCII). PLC automatically
converts the received ASCII data in D1070 ~
D1085 into hex data.
0 - - R NO 0
D1312*
Specify the number of additional pulses for
additional pulses output and Z-phase seeking
function of ZRN instruction (Has to be used with
M1308)
0 0 - R/W NO 0
D1313*
Second of RTC: 00 ~ 59
- - - R/W YES 0
D1314*
Minute of RTC: 00 ~ 59
- - - R/W YES 0
D1315*
Hour of RTC: 00 ~ 23
- - - R/W YES 0
D1316*
Day of RTC: 01 ~ 31
- - - R/W YES 1
D1317*
Month of RTC: 01 ~ 12
- - - R/W YES 1
D1318*
Week of RTC: 1 ~ 7
- - - R/W YES 2
D1319*
Year of RTC: 00 ~ 99 (A.D.)
- - - R/W YES 8
D1320*
ID of the 1
st
right side module
0 - - R NO 0
D1321*
ID of the 2
nd
right side module
0 - - R NO 0
D1322*
ID of the 3
rd
right side module
0 - - R NO 0
D1323*
ID of the 4
th
right side module
0 - - R NO 0
D1324*
ID of the 5
th
right side module
0 - - R NO 0
D1325*
ID of the 6
th
right side module
0 - - R NO 0
D1326*
ID of the 7
th
right side module
0 - - R NO 0
D1327*
ID of the 8
th
right side module
0 - - R NO 0
D1336
PV of Y2 pulse output (Low word)
- - - R/W YES 0
D1337
PV of Y2 pulse output (High word)
- - - R/W YES 0
D1338
PV of Y3 pulse output (Low word)
- - - R/W NO 0
D1339
PV of Y3 pulse output (High word)
- - - R/W NO 0
D1340
Start/end frequency of the 1
st
group pulse output
CH0 (Y0, Y1)
100 - - R/W NO 100
D1343
Ramp up/down time of the 1
st
group pulse output
CH0 (Y0, Y1)
100 - - R/W NO 100
D1348*
When M1534 = ON, D1348 stores the ramp-down
time of CH0(Y0, Y1) pulse output.
100 - - R/W NO 100
D1349*
When M1535 = ON, D1349 stores the ramp-down
time of CH1(Y2, Y3) pulse output.
100 - - R/W NO 100
Page view 75