Delta DVP-ES2 User Manual Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 702
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
2. Programming Concepts
DABSR:
1. M1029= ON when instruction is completed.
2. When the instruction is re-executed for the next time, M1029 will turn off first then ON again
when the instruction is completed
ZRN, DRVI, DRVA:
1. M1029 will be “ON” after Y0 and Y1 pulse output is completed. M1102 will be “ON” after Y2
and Y3 pulse output is compeleted.
2. When the instruction is re-executed for the next time, M1029 / M1102 will turn off first then
ON again when the instruction is completed.
Clear Instruction
Function Group
M1031, M1032
Number
Contents:
M1031 (clear non-latched memory) , M1032 (clear latched memory)
Device Devices will be cleared
M1031
Contact status of Y, general-purpose M and general-purpose S
General-purpose contact and timing coil of T
Clear non-latched area
General-purpose contact, counting coil reset coil of C
General-purpose present value register of D
General-purpose present value register of T
General-purpose present value register of C
M1032
Contact status of M and S for latched
Clear latched area
Contact and timing coil of accumulative timer T
Contact and timing coil of high-speed counter C for latched
Present value register of D for latched
Present value register of accumulative timer T
Present value register of high-speed counter C for latched
Output State Latched in STOP mode
Function Group
M1033
Number
Contents:
When M1033 = ON, PLC outputs will be latched when PLC is switched from RUN to STOP.
Disabling all Y outputs
Function Group
M1034
Number
Contents:
When M1034 = ON, all outputs will turn off.
2-61
Page view 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 701 702

Comments to this Manuals

No comments