AH500 Hardware Manual
9-20
Error
code
Description Remedy
16#9A49
There is no response from slave 9
in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 9.
2. Check the communication cable.
16#9A4A
There is no response from slave
10 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 10.
2. Check the communication cable.
16#9A4B
There is no response from slave 11
in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 11.
2. Check the communication cable.
16#9A4C
There is no response from slave
12 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 12.
2. Check the communication cable.
16#9A4D
There is no response from slave
13 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 13.
2. Check the communication cable.
16#9A4E
There is no response from slave
14 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 14.
2. Check the communication cable.
16#9A4F
There is no response from slave
15 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 15.
2. Check the communication cable.
16#9A50
There is no response from slave
16 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 16.
2. Check the communication cable.
16#9A51
There is no response from slave
17 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 17.
2. Check the communication cable.
16#9A52
There is no response from slave
18 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 18.
2. Check the communication cable.
16#9A53
There is no response from slave
19 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 19.
2. Check the communication cable.
16#9A54
There is no response from slave
20 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 20.
2. Check the communication cable.
16#9A55
There is no response from slave
21 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 21.
2. Check the communication cable.
16#9A56
There is no response from slave
22 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 22.
2. Check the communication cable.
16#9A57
There is no response from slave
23 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 23.
2. Check the communication cable.
16#9A58
There is no response from slave
24 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 24.
2. Check the communication cable.
16#9A59
There is no response from slave
25 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 25.
2. Check the communication cable.
16#9A5A
There is no response from slave
26 in the PLC Link. (SM1592)
1. Check the communication setting in the master, and
the communication setting in slave 26.
2. Check the communication cable.