Delta AH500 series Manual Page 289

  • Download
  • Add to my manuals
  • Print
  • Page
    / 297
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 288
Chapter 9 Troubleshooting
9-25
Error
code
Description Remedy
16#A021
The linear accumulation in
channel 3 exceeds the range.
To clear the linear accumulation, users need to set bit 1 in
CR56 to ON by means of FROM/TO.
16#A022
The prescale value for channel 3
exceeds the range.
Check the module parameter in HWCONFIG.
The prescale value for channel 3 should be within the
range between 0 and 32767.
16#A023
The moving average for channel
3 exceeds the range.
Check the module parameter in HWCONFIG.
The moving average for channel 3 should be within the
range between 2 and 60.
16#A024
The comparison value for
channel 3 exceeds the range.
Check the module parameter in HWCONFIG.
The comparison value for channel 3 should be within the
range between -999999999 and 999999999.
16#A025
The limit value of the alarm output
for channel 3 is incorrect.
Check the module parameter in HWCONFIG.
The limit value of the alarm output for channel 3 should
be within the range between -200000 and 200000.
16#A026
The interrupt number for channel
3 exceeds the range.
Check the module parameter in HWCONFIG.
The interrupt number for channel 3 should be within the
range between 0 and 31.
16#A031
The linear accumulation in
channel 4 exceeds the range.
To clear the linear accumulation, users need to set bit 1 in
CR84 to ON by means of FROM/TO.
16#A032
The prescale value for channel 4
exceeds the range.
Check the module parameter in HWCONFIG.
The prescale value for channel 4 should be within the
range between 0 and 32767.
16#A033
The moving average for channel
4 exceeds the range.
Check the module parameter in HWCONFIG.
The moving average for channel 4 should be within the
range between 2 and 60.
16#A034
The comparison value for
channel 4 exceeds the range.
Check the module parameter in HWCONFIG.
The comparison value for channel 4 should be within the
range between -999999999 and 999999999.
16#A035
The limit value of the alarm output
for channel 4 is incorrect.
Check the module parameter in HWCONFIG.
The limit value of the alarm output for channel 4 should
be within the range between -200000 and 200000.
16#A036
The interrupt number for channel
4 exceeds the range.
Check the module parameter in HWCONFIG.
The interrupt number for channel 4 should be within the
range between 0 and 31.
9.2.3
Troubleshooting for AH05PM-5A/AH10PM-5A/AH15PM-5A
The programs and the setting which are mentioned in the table below are edited in PMSoft version 2.02 or
above.
Error
code
Description Remedy
16#A002 The subroutine has no data. A program should be written in the subroutine.
16#A003
CJ, CJN, and JMP have no
matching pointers.
Write the pointers which match CJ, CJN, and JMP
respectively.
16#A004
There is a subroutine pointer in the
main program.
The subroutine pointer can not be in the main
program.
16#A005 Lack of the subroutine The nonexistent subroutine can not be called.
16#A006
The pointer is used repeatedly in the
same program.
The pointer can not be used repeatedly in the same
program.
16#A007
The subroutine pointer is used
repeatedly.
The subroutine pointer can not be used repeatedly.
16#A008
The pointer used in JMP is used
repeatedly in different subroutines.
The pointer used in JMP can not be used repeatedly in
different subroutines.
Page view 288