Delta AH500 series Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 297
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
AH500 Hardware Manual
3-3
Item
AHCPU500/510/520/530
-RS2
AHCPU500/510/520/530
-EN
Remark
Number of tasks
283 tasks (32 cyclic tasks; 32 I/O interrupts; 4
timed interrupts; 2 communication interrupts; 1
external 24 V low-voltage interrupt; 212 external
interrupts)
Number of input/output
devices
8192 (X0.0~X511.15/Y0.0~Y511.15)
Number of devices
which can be used in
a program
Number of inputs/outputs
AHCPU500: 768
AHCPU510: 1280
AHCPU520: 2304
AHCPU530: 4352
Number of
inputs/outputs
accessible to an
actual input/output
module
Input relays [X]
AHCPU500: 1024 (X0.0~X63.15)
AHCPU510: 2048 (X0.0~X127.15)
AHCPU520: 4096 (X0.0~X255.15)
AHCPU530: 8192 (X0.0~X511.15)
Output relays [Y]
AHCPU500: 1024 (Y0.0~Y63.15)
AHCPU510: 2048 (Y0.0~Y127.15)
AHCPU520: 4096 (Y0.0~Y255.15)
AHCPU530: 8192 (Y0.0~Y511.15)
Internal relays [M] 8192 (M0~M8191)
Link registers [L]
AHCPU500: 16384 (L0~L16383)
AHCPU510: 32768 (L0~L32767)
AHCPU520: 65536 (L0~L65535)
AHCPU530: 65536 (L0~L65535)
Timers [T] 2048 (T0~T2047)
Counters [C] 2048 (C0~C2047)
32-bit counter [HC] 64 (HC0~HC63)
Data register [D]
AHCPU500:16384 (D0~D16383)
AHCPU510: 32768 (D0~D32767)
AHCPU520: 65536 (D0~D65535)
AHCPU530: 65536 (D0~D65535)
Stepping relay [S] 2048 (S0~S2047)
Index register [E] 32 (E0~E31)
Special auxiliary relay [SM] 2048 (SM0~SM2047)
Special data register [SR] 2048 (SR0~SR2047)
Serial communication port
Two
RS-232/RS-485/RS-422
communication ports
One
RS-232/RS-485/RS-422
communication port
Ethernet port - 10/100 M
USB port Mini USB
Storage interface SD Card (SD 1.0)
Remote RUN/STOP The setting range is X0.0~X511.15.
Real-time clock
Years, months, days, hours, minutes, seconds, and
weeks