Chapter 3 Specifications for Products
Analog-to-digital
conversion
Voltage output
Fiducial error
(Room
temperature) (The
number of output
voltages which are
averaged is 100.)
±0.02%
Fiducial error (Full
temperature
range) (The
number of output
voltages which are
averaged is 100.)
±0.04%
Linearity error
(Room
temperature)
±0.004%
Linearity error
(Full temperature
range)
±0.004%
Hardware
resolution
16 bits
Permissible load
impedance
1 k~2 M: ±10 V and 0 V~10 V
500 : 1 V~5 V
Analog-to-digital
conversion
Current output
Rated output
range
0 mA~20 mA 4 mA~20 mA
Hardware output
range
-0.2 mA~20.2 mA 3.8 mA~20.2 mA
Fiducial error
(Room
temperature) (The
number of output
currents which are
averaged is 100.)
±0.06%
Fiducial error (Full
temperature
range) (The
number of output
currents which are
averaged is 100.)
±0.07%
Linearity error
(Room
temperature)
±0.01%
Linearity error
(Full temperature
range)
±0.01%
Hardware
resolution
16 bits
Permissible load
impedance
550