Delta 18-900L Use and Care Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15
SPRING
The spindle will automatically return slowly to its upper
position when the handle is released. However, to adjust,
if necessary:
To reduce the risk of injury, turn unit off
and disconnect it from power source before installing
and removing accessories, before adjusting or when
making repairs. An accidental start-up can cause injury.
1. Remove plastic cap (XX) Fig. 32.
ADJUSTING THE SPINDLE RETURN
2. Loosen nuts (YY) but do not remove. Make sure that the
spring housing (ZZ) remains engaged with head casting
(S).
3. While
holding the spring housing (Fig. 33), pull
out the housing and rotate it (counter-clockwise to
increase or clockwise to decrease) until you feel the
boss (B) engaged with the next notch on the housing.
Tighten the two nuts (YY) Fig. 32 to hold the housing
in place.
IMPORTANT: The inside nut (B1) Fig. 33 should not
contact the spring housing (ZZ) Fig. 33.
4. Replace plastic cap.
PERSONAL INJURY HAZARD. Be careful
not to release the spring housing while adjusting the
spring tension as it may rotate rapidly from the spring
tension.
WW
Fig. 31
AA
Fig. 32
Fig. 33
XX
YY
ZZ
S
B1
ZZ
B
Use care in loosening nut (XX).
DO NOT REMOVE NUT COMPLETELY! Loosen nut (XX)
only enough to make spring housing (YY) rotatable.
Loosening nut too much can be dangerous and cause
personal injury. Spring inside housing is under tension
and will try to unwind if not held securely. Spring
housing should still be held snugly to head casting by
the nut but be loose enough to rotate the spring
housing to desired spring tension.