NOTE: Control Box #0 and #1 are designed for routine 171°F (77°C)
disinfection cycles up to 30 minutes.
Control Box #8 is not recommended for high temperature disinfection
cycles as the thermostatic mixing valve limits the higher temperature
flow output.
NOTE: For optimum performance of this product, we recommend a
system pressure between 20 and 80 PSI static. This product will
operate up to a maximum of 125 PSI static per ANSI and CSA
requirements. However, we do not recommend pressure above 80
PSI. Thermal expansion or leaking pressure reducing valves may
require the use of expansion tanks or relief valves to ensure your
system never exceeds its maximum intended pressure setting.
RP30523
Braided Hose
063131A
3/8” x 3/8”
Compression
Connector,
Nut and
Ferrule
060765A
Wrench
060683A
24 VAC/6.4 VDC
Converter
Fig. 1
063127A
Solenoid
Valve with
3/8”
Compression
Connectors
061256A
36” Cable Extension
Accessories
OPTION LIST
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
060772A
Transformer 110 to 24 VAC 100VA
up to 25 Electronic Valves
DECK PLATES
060546A
4” Deck Plate & Hold-Down Pkg
060547A
8” Deck Plate & Hold-Down Pkg
RP6087
Nut and Washer
208356 208356 208356 208356
208356 208356 208356 208356
Note: See page 3 for
parts breakdown on
recessed mount boxes.
060546A
4” Deck Plate and
Hold-Down Package
060547A
8” Deck Plate and
Hold-Down Package
RP6092
Nut and Washer
060638A
Vandal Resistant Laminar Outlet
with Antimicrobial by Agion
®
1.5 GPM (5.7 L/min)
060640A
Vandal Resistant Flow Control
Aerator and Wrench
1.5 GPM (5.7 L/min)
061203A
Vandal Resistant Laminar
Outlet with Wrench
0.5 GPM (1.9 L/min)
061176A
Vandal Resistant Laminar
Outlet with Wrench
1.0 GPM (3.8 L/min)
061104A
Vandal Resistant Flow Control
Non-Aerating Spray Outlet
with Wrench
0.35 USGPM (1.3 L/min)
RP31704 - Optional
Vandal Resistant Spray
Outlet with Wrench
0.5 GPM (1.9 L/min)
060566A - Optional
Vandal Resistant Spray
Outlet with Wrench
1.0 GPM (3.8 L/min)
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
www .specselect.com
060564A
Single Hole Deck
Gasket (6/pkg)
063210A
Spout Assembly
060681A
Battery Holder
063128A
Battery Box Assembly less driver
board and battery holder
063131A
3/8” Comp Connect Nut
and Ferrile
060909A
Screen Assembly
060908A
Solenoid Holder
063127A
Solenoid Valve with 3/8”
Compression Connectors
061252A
Dual Driver Board
Masco H
2
Optics
& Proximity
060906A
Surface
Mount Housing
060905A
Cover Gasket
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - 590T_ _ _ _

Page 1208356 Rev. C590T_ _ _ _Write purchase model number here for future reference NOTE: Control Box #0 and #1 are designed for routine 171°F (77°C

Page 2 - 208356 Rev. C

7" (178 mm)Max.13" (331 mm) Max.NOTE: Entire connection can be placedinside battery box if desired.Fig. 2 Tie WrapsPage 2208356 Rev. CFOR

Page 3 - STEP 2. FAUCET INSTALLATION

Page 3208356 Rev. Cwww .specselect.comFOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8 INSTALLATION AND SET UP INSTRUCTIONSInstallation should

Page 4 - STEP 6. SERVICES

SensorWatertightConnectorFlexibleSensorCord ConduitSUPPLIED:3/8” MIP Outlet from Box3/8” Compression Joint at SpoutBALANCE BY OTHERS257mm (10.13"

Page 5 - STEP 8. MAKING ADJUSTMENTS

Minimum RecommendedDistance 9" (229mm)Sensing Zone9" (228mm) default1"(25mm)Operation IllustrationPage 5208356 Rev. CFOR RECESS MOUNT

Page 6 - BATTERY STRENGTH INDICATOR

Page 6208356 Rev. Cwww .specselect.comSENSOR RANGE (d)The sensor range is the maximum distance at which the user is detected. The sensor range sett

Page 7 - CARE INSTRUCTIONS

Page 7208356 Rev. CTROUBLESHOOTING GUIDECheck to ensure faucet was installedaccording to the M&I sheet.Test for operation. If unit does notoper

Page 8

Delta Commercial Faucet Limited WarrantyGarantía Limitada de las Llaves de Agua Comerciales DeltaGarantie Limitée Delta CommercialAll parts of the Del

Comments to this Manuals

No comments