203910
Rev.A
FOR SURFACE MOUNT HOUSING: CONTROL BOX #0
STEP 1. FAUCET INSTALLATION
Connect 20” braided hose to spout inlet. Mount faucet to sink using nut(s) and
washer(s) provided.
(Fig. 1) NOTE: Use clear silicone sealant between faucet
and lavatory to prevent water from leaking beneath lavatory.
STEP 2. BATTERY BOX INSTALLATION
Mount battery box to wall under sink using the 4 supplied screws and anchors.
Use 1/4” drill for wall anchors.
Be sure to install the box within the dimensions
provided so the hose and spout cable will reach connections at faucet and
battery box. Refer to illustration (Fig. 2).
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 3) and run water
for 1 minute. Shut off water supply. Attach aerator.
NOTE: Do not connect supply
to the solenoid inlet until line is flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 4) supply
line and adaptor to the bottom fitting on box, braided hose to the top fitting on
box. Use Teflon® tape where indicated on adaptor. Turn on water supply.
DO
NOT SOLDER CONNECTIONS!
STEP 5. POWER UP
Unscrew the battery box lid screws (2). Install four “C” batteries in holder or snap
the battery clip directly to the optional 24 VAC converter.
BATTERY VERSION Install four “C” batteries provided into the battery box. After
the batteries are installed, make the sensor connection on the driver board neatly
inside the battery box. Connect battery clip to battery pack. One beep should
occur to indicate power is applied. Two beeps indicate product is ready to use.
Use caution not to damage wires or components on electronic driver board.
See
Fig. 5.
Secure lid using screws.
HARDWIRE VERSION Install CSA and/or UL approved Class 2 transformer or
equivalent in a convenient location or in a pipe chase.
(Do NOT install the
transformer inside the control box.)
With the power off, bring the 24 VAC
supply wires to the box. Connect the 24 VAC supply to the 060683A conversion
kit, (See Page 1.) Connect the battery snap of the hardwire converter to the driver
board battery clip. Turn on power supply for the transformer and then make the
sensor connection on the control module neatly inside the battery box.
STEP 6. PREPARE SINK AREA
Before connecting the spout cable – clean off counter and remove all
objects from the sink.
STEP 7. TIE SPOUT CABLE
Attach spout cable to box connector. Use tie wraps to secure spout cable to
spout hose. Your faucet is now ready for use.
(Fig. 2)
STEP 8. TEST FOR OPERATION
Test for operation. If faucet leaks from spout outlet: SHUT OFF WATER
SUPPLIES. Replace Battery Box Assembly (1). If faucet exhibits very low flow: A.
Remove and clean Spray Outlet or B. SHUT OFF WATER SUPPLY. Clean or
replace Screen Assembly (2). If unit does not work properly, see Trouble Shooting
Guide on Page 5.
3/8" O.D.
Copper
Inlet
Bypass
Adapter
Ferrule
Nut
Spout
Hose
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
7" (178 mm)
Max.
13" (331 mm) Max.
Tie Wraps
NOTE: Entire connection can be
placed inside battery box if desired.
Teflon
®
Tape
Fig. 2
Fig. 3 Fig. 4
Trap
jacket of
cable in
hole for
strain
relief.
NOTE: Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.
2
1
Fig. 5
Page view 1
1 2 3 4 5 6 7

Comments to this Manuals

No comments