Delta 591T1250 Installation Guide Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
Page 3
203910
Rev.A
FOR RECESS MOUNT HOUSING: CONTROL BOXES #1, 6, 8.
STEP 1. ROUGH IN
HARDWIRE Remove suitable knockout(s) in box(es) and insert cable bushing(s). See Fig. 6.
Note:
Wires connecting between box(es) and from transformer must be protected from abrasion,
and being pulled at connections. They also may have to be fished through at a later stage of
construction. Depending on installation, the cable bushings included may be replaced by
installer
supplied
1/2” conduit. Rough-in box as per Fig. 10.
The transformer is to be installed in an adjacent accessible space.
(Do NOT install the
transformer inside the control box.)
Cable from the transformer to the driver board may be
roughed in at this time depending on installation. Use cable which complies to local electrical
codes for a 1 amp. load. No. 18 is usually sufficient.
HARDWIRE OR BATTERY If recessed box is supplied, rough in as per Fig. 10. The most vandal
resistant installation is when the control box is as close to the bottom of the sink as feasible. For
wall hung sink installation, sensor conduit rough in should be directly under the basin to minimize sensor cord exposure.
Rough in drainage. Rough in water supply to 10” control box inlets and to spout connection. Finish walls.
STEP 2. FAUCET INSTALLATION
Mount faucet to sink using nut(s) and washer(s) provided. (Fig. 1)
NOTE: Use clear silicone sealant between faucet and lavatory to prevent water from leaking beneath lavatory.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
Knockouts
Cable Bushing
Fig. 6
COVERS
060577A 060073A
12” Stainless Steel Cover Screws (4/pkg) and driver bit for covers
Bracket
and
battery
holder not
required
for
hardwire
models
Flexible Sensor
Cord Conduit
(Supplied on
recessed mount box)
060829A
Screwdriver Stops with Check
060911A
Mechanical
Mixing Valve
060907A
Driver board
to be located
on this
bracket
Outlet
3/8” M.I.P.
Inlets 1/2”
Copper
Outlet
3/8" M.I.P.
Tempered Water
(By Others)
Inlet:
1/2" Copper
060576A
Screwdriver
Stop
Flexible Sensor
Cord Conduit
(Supplied on Recessed
Mount Box)
060671A
3/4” NPS
Solenoid
Valve
060907A
Driver
board
to be
located
on this
bracket
Bracket
and
battery
holder not
required
for
hardwire
models
Flexible Sensor
Cord Conduit
(Supplied on
recessed mount box)
060912A
Thermostatic Mixing Valve
060907A
Driver board
to be located
on this bracket
Outlet
3/8” M.I.P.
Inlets 1/2”
Copper
060829A
Screwdriver Stops with Check
Control Box #1 Control Box #6 Control Box #8
Fig. 7 Fig.8 Fig. 9
Page view 2
1 2 3 4 5 6 7

Comments to this Manuals