FOR RECESS MOUNT HOUSING: CONTROL BOXES #1, 6, 8.
STEP 3. CONNECT WATER SUPPLY
Install sink and connect drainage to rough in. See
applicable
Fig. 7, Fig. 8 or Fig. 9. Please note that the
connection tube and fittings are supplied by the
installer to connect the 3/8” MIP at the box outlet and
compression joint for 3/8” O.D. Soft copper tube at the
spout. Connect water supply through to spout. Assure
supply lines are completely flushed and free of debris.
STEP 4. FLUSH SYSTEM/SET TEMPERATURE
Remove coverplate from control box. Open screwdriver
stop(s) to flush installation for
1 minute minimum.
4A Run water for a sufficient time so the hot and cold
water supplies are as hot and cold as they will get.
4B Place a thermometer in a plastic container and hold
in the water stream. Record the temperature
reading and note position of temperature control,
and lock at desired setting.
4C If Mechanical Mixing Valve (060911A) (Fig. 8)
Adjust setting to the desired temperature and lock
in place by tightening the vandal resistant screw.
If
Thermostatic Mixing Valve (Fig. 9) Adjust setting of
the Thermostatic Mixing Valve to obtain the desired
temperature (counterclockwise, to increase temperature
– clockwise to decrease temperature). (
Fig. 11)
Periodic Inspection/Maintenance – This valve requires
periodic inspection and verification of the outlet
temperature by a licensed contractor. Corrosive water
conditions, hot feed water temperatures over 200ºF
(93ºC), unauthorized adjustment or repair could render
the valve ineffective for its intended service. Regular cleaning and checking of thermostat
assembly helps to maximize valve life and mixing function. Frequency of cleaning depends on
local water conditions.
4D Close stop(s).
STEP 5. CONNECT ELECTRICAL SUPPLY, SOLENOID VALVE AND SENSOR
Remove plastic threaded spacer nipple and install solenoid valve with body arrow in the
direction of water flow.
See Fig. 12. Feed sensor wire from spout into control box and then into
the battery box. Connect red solenoid cord to “+” marked solenoid terminal on solenoid valve,
black solenoid cord to other solenoid terminal.
BATTERY VERSION Remove cover from control box and install four “C” batteries provided into
the battery holder. After the batteries are installed, make the sensor connection on the driver
board. Connect battery clip to battery pack. One beep should occur to indicate power is applied.
Two beeps indicate product is ready to use. Use caution not to damage wires or components on
electronic driver board. Secure cover using screws.
HARDWIRE VERSION Install CSA and/or UL approved Class 2 transformer or equivalent in a
convenient location or in a pipe chase.
(Do NOT install the transformer inside the control box.)
With the power off, bring the 24 VAC supply wires into the box. Connect the 24 VAC supply to
the 060683A conversion kit. Connect the battery snap of the hardwire converter to the driver
board battery clip. Turn on power supply for the transformer and then make the sensor
connection on the driver board neatly inside the box. Secure cover using screws.
INSTALLATION AND SET UP INSTRUCTIONS
Turn
Colder
Hotter
Fig. 11
Watertight
Connector
Flexible,
Sensor
Cord Conduit
SUPPLIED:
3/8" MIP Outlet from Box
3/8" Compression Joint at Spout
BALANCE BY OTHERS
257mm
(10.13")
Control Box
305mm (12")
102mm (4")
Stainless Steel
Cover Plate
355mm
(14")
max.
Sensor
Fig. 10
Valve
Spacer
(Replace
with
SOLENOID
Valve after
system is
flushed)
Cover
Solenoid Valve
(INSTALL:
replacing
SPACER after
system is
flushed.)
SOLENOID
may be
ROTATED to
ALLOW for installation
of COVER ASSEMBLY.
Fig. 12
Product supplied
as shown by
solid lines. All
items shown by
dotted lines
supplied by
others.