to use the popup editor. You can enter hexadecimal numbers by typing a leading 0x,as
in 0x1FE0. Each of the eight faults listed above has two bits assigned to it, label S and H
in the table below:
Bit Description Bit Description
15 Fault 7 - Bit S 7 Fault 7 - Bit H
14 Fault 6 - Bit S 6 Fault 6 - Bit H
13 Fault 5 - Bit S 5 Fault 5 - Bit H
12 Fault 4 - Bit S 4 Fault 4 - Bit H
11 Fault 3 - Bit S 3 Fault 3 - Bit H
10 Fault 2 - Bit S 2 Fault 2 - Bit H
9 Fault 1 - Bit S 1 Fault 1 - Bit H
8 Fault 0 - Bit S 0 Fault 0 - Bit H
For each fault, the two bits in the Auto Stop parameter define the action as follows:
Bit H Bit S Description
00StatusOnly
01SoftStop
10HardStop
11HardStop
If you select Status Only for a fault that cannot use that action, then the axis will use a
Soft Stop action for that fault.
AUTO STOP Bit Map
This table provides an easy method to convert bit patterns to hexadecimal numbers.
F 1111 1111 1111 1111
E 1110 1110 1110 1110
Hexadecimal To D 1101 1101 1101 1101
Binary Conversion C 1100 1100 1100 1100
Table B 1011 1011 1011 1011
A 1010 1010 1010 1010
9 1001 1001 1001 1001
8 1000 1000 1000 1000
7 0111 0111 0111 0111
6 0110 0110 0110 0110
5 0101 0101 0101 0101
4 0100 0100 0100 0100
3 0011 0011 0011 0011
2 0010 0010 0010 0010
1 0001 0001 0001 0001
0 0000 0000 0000 0000
_______ _______ _______ _______
||||||||||||||||||||
||||||||||||1|1|1| |1|1|1|1|
|1|2|3|4| |5|6|7|8| |9|0|1|2| |3|4|5|6|
Bit Definition |_|_|_|_| |_|_|_|_| |_|_|_|_| |_|_|_|_|
---------------- //// //// //// ////