60
G
Current Output 2
H
Common
J
Current Output 1
Hardware Specifications
Inputs
Indicators
Input Impedance
Input voltage range
Overvoltage protection
Outputs
Output current range
Conversion Accuracy
Offset
Two per unit
1 dual color LED per channel;
Green = positive input,
Red = negative, intensity indicates
amplitude
40k
±10V
±100V (Outputs may reverse polarity if
inputs are above power supply voltages)
Two per unit
±10mA to ±100mA, switch-selectable (See
the Output Characteristics table for more
information)
0.6% full scale, typical, all ranges
0.05% typical, ±100mA range
0.5% typical, ±10mA range
Power Supply Requirements
Voltage ±12 VDC to ±15 VDC
Current ±50mA plus load current (±250mA
maximum)
Isolation There is no isolation between inputs,
outputs, and power supplies. If isolation
is required, it must be done external to the
VC2100 (Delta motion control modules
provide isolated voltage outputs).
Protection Power supply inputs are protected against
over-voltage, spikes, and reverse voltage.
User should fuse with appropriate fast-
blow fuse.
Mechanical Specifications
Dimensions
Weight
Mounting
Connectors
0.94 x 2.94 x 3.94 in (2.4 x 7.5 x 10.0 cm)
3.5oz (100 g)
Mounts directly to DIN rail
Cage clamp terminal blocks integrated into
package
Environment
Operating temp.
Storage temp.
+32to+140°F(0to+60°C)
-40 to +185°F(-40to+85°C)