MMC120 Linear Motion Control Module Motion Control Parameters
Delta Computer Systems, Inc. 360/254-8688 37
MODE Word Bit Map
The axis MODE word contains 16 bits of information. This hexadecimal table provides an easy way to
convert hexadecimal numbers to bit patterns.
F 1111 1111 1111 1111
E 1110 1110 1110 1110
Hexadecimal To D 1101 1101 1101 1101
Binary Conversion C 1100 1100 1100 1100
Table B 1011 1011 1011 1011
A 1010 1010 1010 1010
9 1001 1001 1001 1001
8 1000 1000 1000 1000
7 0111 0111 0111 0111
6 0110 0110 0110 0110
5 0101 0101 0101 0101
4 0100 0100 0100 0100
3 0011 0011 0011 0011
2 0010 0010 0010 0010
1 0001 0001 0001 0001
0 0000 0000 0000 0000
_______ _______ _______ _______
||||||||||||||||||||
||||||||||||1|1|1| |1|1|1|1|
|1|2|3|4| |5|6|7|8| |9|0|1|2| |3|4|5|6|
Bit Definition |_|_|_|_| |_|_|_|_| |_|_|_|_| |_|_|_|_|
---------------- //// //// //// ////
Graph Disable ------------ 01 -//// //// //// ////
Reserved ----------------- 02 --/ / / //// //// ////
Reserved ----------------- 03 ---/ / //// //// ////
Reserved ----------------- 04 ----/ //// //// ////
//// //// ////
Reserved ----------------- 05 ------//// //// ////
Reserved ----------------- 06 -------/ / / //// ////
Reserved ----------------- 07 --------/ / //// ////
Reserved ----------------- 08 ---------/ //// ////
//// ////
S-Curve ------------------ 09 -----------//// ////
Reserved ----------------- 10 ------------/ / / ////
Quick Mode --------------- 11 -------------/ / ////
Sync --------------------- 12 --------------/ ////
////
Integrator Mode ---------- 13 ----------------////
Integrator Mode ---------- 14 -----------------/ / /
Accel and Decel Mode ----- 15 ------------------/ /
Accel and Decel Mode ----- 16 -------------------/