MMC120 Linear Motion Control Module Appendix A: DCS120
Delta Computer Systems, Inc. 360/254-8688 79
Initial Startup Using Motion Control Module
Before DCS120 can be used with a Motion Control Module you must connect the appropriate hardware. Refer to pages
17-19 for hardware connection information.
Once you have connected the hardware, you must configure DCS120 to match it. Insert the DCS120 disk in drive A
and type a:install <Enter> (you can substitute drive B for A). Select the directory where you want to install DCS120.
You may need to select a different COMM port. Please see explanations of the various configuration files later in this
appendix. When you finish the installation, change to the DCS120 directory (default: c:\DCS120) and type MMCDOS
<Enter> to start the program.
The following is a sample of a typical system screen:
MMC120 0.99 DEL TA Computer Systems, Inc. MMC120
19990709
PLOT TYPE 0 0 3X+0 3X+1 3X+2 3X+3
PLOT TIME 1 1
Axis1 Axis2 Axis1 Axis2 4X+0 4X+1 4X+2 4X+3
COMMAND POS. 0 0 CONFIG 00000 00000 00000 0|00000 0
TARGET POS. 0 0 SCALE 30300 30300 00000 0 00000 0
ACTUAL POS. 0 0 OFFSET 0 0 00000 0 00000 0
COUNTS 0 0 EXTEND LIMIT 50000 50000 00000 0 00000 0
STATUS 00000 00000 RETRACT LIMIT 1000 1000 00000 0 00000 0
DRIVE 0 0 PRO. GAIN 100 100 00000 0 00000 0
ACTUAL SPEED 0 0 INT. GAIN 100 100 00000 0 00000 0
NULL DRIVE 0 0 DIF. GAIN 10 10 00000 0 00000 0
STEP 0 0 EXT. FEED FWD. 100 100 00000 0 00000 0
LINK VALUE 0 0 RET. FEED FWD. 100 100 00000 0 00000 0
MODE 00001 00001 EXT. ACCEL FF. 50 50 00000 0 00000 0
ACCEL 1000 1000 RET. ACCEL FF. 0 0 00000 0 00000 0
DECEL 1000 1000 DEAD BAND ELIM 0 0 00000 0 00000 0
SPEED 1000 1000 IN POSITION 5 5 00000 0 00000 0
COMMAND VALUE 0 0 FOLLOW ERROR 50 50 00000 0 00000 0
COMMAND AUTO STOP 00000 00000 00000 0 00000 0
AXIS 1 COMMAND POS. : 0 INPUT> _ W F
Screen After Installation
NOTE: After installation, if the screen contains all zeros in the Read Only (green) section, there is a problem with the
hardware connections and/or DCS120's configuration information. Recheck the hardware and re-install DCS120
while double checking the specified setup parameters.