RMC100 and RMCWin User Manual
4-38
Note the good design practices:
Metal tubing between valve and cylinder.
An accumulator close to valve.
Use of a zero-overlap valve.
2. Wiring
It is important to wire the transducer correctly. See MDT Wiring and Analog Wiring for details.
For this example the system is wired as follows:
The pressure transducers are wired to the Analog module channels 0 and 1
The position feedback is wired to MDT channel 0
The MDT Drv 0 is wired to the valve.
3. RMCWin View
When connected to this RMC, the main RMCWin window looks as follows: