RMC100 and RMCWin User Manual
5-70
• RMC Register Map (Siemens S7)
• RMC Register Map (Modbus Plus)
• RMC Register Map (PROFIBUS-DP Message Mode)
Allen-Bradley offers several Ethernet and serial solutions for its ControlLogix, SLC, PLC-5, and
SoftLogix 5 controllers. In addition, SoftPLC emulates the PLC-5 and therefore also uses Allen-
Bradley's Ethernet protocol. Over this protocol, the RMC's registers are broken into a number of
integer files. Each integer file used (N7, N9-N18, L19, N20-N255) is configured to be the
maximum size allowed on a SLC 5/05 file: 256 elements: Nf:0-255. For details on reading and
writing these registers, see the following topics:
• Using Allen-Bradley Controllers with the RMC ENET
• Using SoftPLC's SoftPLC with the RMC ENET
• Using DF1 (Full- and Half-Duplex) with the RMC SERIAL
Status Registers:
These registers can only be read; writes are ignored.
Bradley
and SoftPLC
Register Description
Axis 0 Transducer Counts.
Note: See the Transducer Counts (32-bit)
Registers section below for a way to read
32-bit counts instead of 16-bit counts.
Same as above but for axis 1
Same as above but for axis 2