Delta RMC101 User Manual Page 375

  • Download
  • Add to my manuals
  • Print
  • Page
    / 951
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 374
Ethernet 5.2
Communications 5-125
Modbus
Address
Register Description
2305
Event Step for Axis 0 on Input 0 Rising Edge
2306
Event Step for Axis 1 on Input 0 Rising Edge
2307
Event Step for Axis 2 on Input 0 Rising Edge
2308
Event Step for Axis 3 on Input 0 Rising Edge
2309
Event Step for Axis 4 on Input 0 Rising Edge
2310
Event Step for Axis 5 on Input 0 Rising Edge
2311
Event Step for Axis 6 on Input 0 Rising Edge
2312
Event Step for Axis 7 on Input 0 Rising Edge
2313 + n
Event Step for Axes n (0-7) on Input 1 Rising
Edge
:
:
2425 + n
Event Step for Axes n (0-7) on Input 15
Rising Edge
2433 + n
Event Step for Axes n (0-7) on Input 0 Falling
Edge
:
:
2553 + n
Event Step for Axes n (0-7) on Input 15
Falling Edge
Status Map Registers:
This block of registers is only used by the Modbus Plus and PROFIBUS interfaces. Therefore,
these registers are unused by this Ethernet protocol.
Modbus
Address
Register Description
2561-
2592
Status Map Entries
Plot Type Registers:
The plot type registers can be read or written. The values that are read indicate the extra plot
information in the current graph. The values written to these registers tell the controller which
extra plot information to obtain on the next plot. For these registers, the following values are used:
0: Extra position precision
1: Command and Command Value
Page view 374
1 2 ... 370 371 372 373 374 375 376 377 378 379 380 ... 950 951

Comments to this Manuals

No comments