RMC100 and RMCWin User Manual
5-158
N159:255
N160:0-
N183:255
Plot data for axis 4
N184:0-
N207:255
Plot data for axis 5
N208:0-
N231:255
Plot data for axis 6
N232:0-
N255:255
Plot data for axis 7
5.2.6.7 Siemens Simatic TI505
5.2.6.7.1 Using the Siemens Simatic TI505 with the RMC Ethernet Module
The TI505 does not have built-in Ethernet TCP/IP support. However, Control Technology, Inc.
sells a module called the CTI 2572 that fits into the TI505 backplane and adds Ethernet TCP/IP to
the TI505.
When using this module, the CTI uses a combination of V-memory registers, and I/O registers
(WX and WY) on the CTI 2572 itself to communicate from the TI505 ladder logic. It is beyond the
scope of this manual to fully describe using the CTI 2572; please refer to the CTI 2572 Ethernet
TCP/IP Adapter Installation and Operation Guide (Part #062-00146) that is shipped with the CTI
2572.
The CTI 2572 can read, write, or do a combined read and write from registers in compatible
remote devices such as other TI505 PLCs with the CTI 2572 module or the RMC. The RMC has
65536 registers that are accessible from the CTI 2572. See RMC Register Map (Siemens TI505)
for details on those registers and their addresses.
If you need help setting up your network, either consult your network administrator, or for simple
stand-alone networks, see Setting up a Stand-alone TCP/IP Control Network.
5.2.6.7.2 RMC Register Map (Siemens TI505)
Tip: RMCWin's Address Tool provides an easy way to identify addresses in the RMC. Simply open the
Address Tool and then move the cursor to any field in RMCWin that represents an RMC Register, and
the Address Tool will display the address in the address format of your choice. See Address Tool for
details.
The RMC module has 64K (65536) 16-bit registers that can be read from or written to over
Ethernet, Modbus Plus, and PROFIBUS-DP. Each register is assigned an address. However,
under the different communication methods, different addressing schemes are used. This topic
describes the addressing from a TI505 using the CTI 2572 Ethernet TCP/IP module. For details
on addressing from other modules refer to the following topics:
RMC Register Map (Allen-Bradley)
RMC Register Map (Automationdirect.com)