RMC100 and RMCWin User Manual
5-166
2657 Boot firmware month (MSB) and day (LSB)
2658 Boot firmware year
2659 Loader firmware month (MSB) and day (LSB)
2660 Loader firmware year
2661
Control firmware month (MSB) and day
(LSB)
2662
Control firmware year
2663
Control firmware Beta Code. This will be 0
for standard release firmware, 'B' for Beta
firmware, or 'SI' for Superimposed firmware.
2664
Feature code. This register is mainly
reserved for internal use but does have two
bits that may be useful to some users:
If bit 1 (value 0x0002) is set, the control loop
is 2 ms, otherwise the control loop is 1 ms.
If bit 0 (value 0x0001) is set, a sensor DI/O is
present, otherwise there is no sensor DI/O.
Reserved Registers:
Reading these values will return zero, and writes are ignored.
TI505
Address
Register Description
2665-
12288
Unused
Spline Download Area:
These registers are write only. Reading them will return zero. This area is used to download
intervals and points in a spline. This is a much more efficient alternative to using individual New
Spline Point and Set Spline Interval/End Segment commands. For details on using this Spline
Download Area, see Downloading Splines to the RMC.
TI505
Address
Register Description
12289-
16384
Spline Download Area
Plot Registers:
These registers can only be read; writes are ignored.