Delta RMC101 User Manual Page 596

  • Download
  • Add to my manuals
  • Print
  • Page
    / 951
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 595
RMC100 and RMCWin User Manual
6-52
Note: Prior to RMC CPU firmware dated 19991216, the Auto Stop parameter was not used in
determining the LED states. Therefore, the only way to keep the LED from showing red was to
clear the error.
See also:
Stepper Overview
Stepper Wiring
Stepper Configuration
Stepper Specifications
Stepper Scaling
Stepper Compensation
Homing
6.4.5 Stepper Specifications
For general specifications on the RMC, see RMC100 Specifications.
Encoder
Axes
Two per module
Encoder Inputs
RS422 differential receiver
Quadrature A, B, and Index Z
ESD Protection
15 kV
Max. Encoder Frequency
4,000,000 counts/second
Index (Z) Response Time
63 nanoseconds
Inputs and Outputs
Fault Inputs, Home
Inputs, and Limit Inputs
(Ext. & Ret.)
2.7 V @ 2.8 mA typical (3.2 V @ 3.5 mA max)
threshold, 26.4 V maximum input voltage, 500
VDC isolation, compatible with most limit
switches, TTL, and CMOS outputs
Drive Enable Output
(1 per axis)
Solid State relay, 50 W, 30 V, 100 mA
500 VDC isolation
Vcc Out
5 V ±20% @ 50 mA for use with Step, Direction,
and Enable outputs. DO NOT power encoders
with this output. See Stepper Wiring for details.
Motor Interface
Step and Direction
Outputs
RS422 (5 V differential)
Pulse Width
50% duty cycle ± 80 nanoseconds
Max. Output Frequency
1 MHz
Page view 595
1 2 ... 591 592 593 594 595 596 597 598 599 600 601 ... 950 951

Comments to this Manuals

No comments