SSI 6.6
Transducer Interface Modules 6-75
occurred:
No Transducer
Transducer Noise
Transducer Overflow
Alternating Red/Green
None of the above errors
occurred, and one or more of the
below errors have occurred and
are enabled in the Auto Stop:
Overdrive Error
Parameter Error
Position Overflow
Integrator Windup
Following Error
Continuous Green
Status good. None of the above
are true.
Note: Prior to RMC CPU firmware dated 19991216, the Auto Stop parameter was not used in
determining the LED states. Therefore, the only way to keep the LED from showing red was to
clear the error.
See also:
SSI Overview
SSI Wiring
SSI Configuration
SSI Specifications
6.6.5 SSI Specifications
For general specifications on the RMC, see RMC100 Specifications.
Transducer Inputs
Axes
Two per module
Inputs
Two RS422 differential
Clock outputs
Two RS422 differential