Appendix A: Command Reference
A-53
details.
A.2.10 Set Pressure Set B Command
Character: _
Decimal: 95
Hexadecimal: 0x5F
Command Value: Pressure Value
This command sets the Pressure Set B value to the Command Value. The new value for
Pressure Set B is used as soon as the command is processed. Refer to Pressure Set B for
details.
A.2.11 Set Parameter On-the-Fly
Character: None
Decimal: 208-223
Hexadecimal: 0xD0-0xDF
Command Value: Value of the Parameter
Note: This command is supported in RMC100 CPU firmware dated 19980414 or later.
Each of these commands sets one of the parameters. The following table can be used to
determine which command sets which parameter. Reference axes parameters cannot be set on-
the-fly. Notice that some parameters can never be set on the fly:
Command
MDT, SSI, Quad,
Analog (Position)
Stepper
Pressure/force
Hex
Decimal
Parameter
Parameter
Parameter
0xD0
208
Config. Word
Invalid command
Invalid command
0xD1
209
Scale (2) (4)
Invalid command
Invalid command
0xD2
210
Offset (1)
Coordinate Limit (2)
Invalid command
0xD3
211
Extend Limit (1)
Extend Limit (2)
Invalid command
0xD4
212
Retract Limit (1)
Retract Limit (2)
Invalid command
0xD5
213
Proportional Gain
Compensation Rate (2)
Proportional Gain
0xD6
214
Integral Gain
Compensation Timeout
(2)
Integral Gain
0xD7
215
Differential Gain
Invalid command
Differential Gain