Appendix A: Command Reference
A-59
The following table lists all commands that can be issued over the RMC’s PROFIBUS-DP
Compact Mode:
1111|11 | |
Bit#5432|1098|7654|3210
-------------------
0000|RRRR|0000|0000 No command
0000|RRRR|0000|CCCC Open Loop Using Profile
0000|RRRR|0001|CCCC Set Parameter
0000|RRRR|0010|CCCC Set Profile
0000|RRRR|0011|XXXX Reserved
0000|RRRR|01CC|CCCC ASCII Commands
0000|RRRR|1000|CCCC Go/Set Pressure Using Profile
0000|0000|1001|CCCC Get Parameter
0000|0000|1010|CCCC Get Profile
0000|RRRR|1011|XXXX Reserved
0000|RRRR|1100|XXXX Reserved
0000|RRRR|1101|CCCC Set Parameter On-the-fly
0000|RRRR|1110|00CC Event Step Edit
0000|0000|1111|0000 Diagnostics
0001|XXXX|XXXX|XXXX Reserved
0010|CCCC|CCCC|CCCC Download Graph Data
: : :
1101|CCCC|CCCC|CCCC Download Graph Data
1110|CCCC|CCCC|CCCC Event Step Transfer
1111|XXXX|XXXX|XXXX Reserved
Refer to the sections below for descriptions of using each of these types of bits (C, R, and X):
C (Command) Bits:
Page view 710
1 2 ... 706 707 708 709 710 711 712 713 714 715 716 ... 950 951