RMC100 and RMCWin User Manual
A-62
-------------------
HEX |SAR |CMND|INDX
VALUE -------------------
0X00 0AAA|XXXX|0000|0000 NO COMMAND
0X01 0AAA|XXXX|0000|0001 OPEN LOOP USING PROFILE 1
0X02 0AAA|XXXX|0000|0010 OPEN LOOP USING PROFILE 2
0X03 0AAA|XXXX|0000|0011 OPEN LOOP USING PROFILE 3
0X04 0AAA|XXXX|0000|0100 OPEN LOOP USING PROFILE 4
0X05 0AAA|XXXX|0000|0101 OPEN LOOP USING PROFILE 5
0X06 0AAA|XXXX|0000|0110 OPEN LOOP USING PROFILE 6
0X07 0AAA|XXXX|0000|0111 OPEN LOOP USING PROFILE 7
0X08 0AAA|XXXX|0000|1000 OPEN LOOP USING PROFILE 8
0X09 0AAA|XXXX|0000|1001 OPEN LOOP USING PROFILE 9
0X0A 0AAA|XXXX|0000|1010 OPEN LOOP USING PROFILE 10
0X0B 0AAA|XXXX|0000|1011 OPEN LOOP USING PROFILE 11
0X0C 0AAA|XXXX|0000|1100 OPEN LOOP USING PROFILE 12
0X0D 0AAA|XXXX|0000|1101 OPEN LOOP USING PROFILE 13
0X0E 0AAA|XXXX|0000|1110 OPEN LOOP USING PROFILE 14
0X0F 0AAA|XXXX|0000|1111 OPEN LOOP USING PROFILE 15
Note: When this command’s index is zero (0), it is treated as though no new command is given.
The command data represents the requested drive in millivolts.
Example for PROFIBUS-DP in Compact Mode with Sync:
Suppose you would like axis 0 to go into open loop at 2000mV of drive using profile 10 and axis 1
to go into open loop at 4000mV of drive using profile 11. You would send the commands in the
following format:
SAR CMND INDX (HEX)
O+1 0000|XXXX|0000|1010 (0X0A)
Issue an Open Loop using Profile 10
command
+2 2000 (07D0)
Requested Drive