RMC100 and RMCWin User Manual
E-30
1. Select the Link Type:
Use 'P' to compare with the Actual Pressure, 'p' to compare with the Target Pressure.
2. Enter the Limit Pressure in the Link Value.
E.5.4 Link Type - Current Axis Speed
Link
Type:
TarSpd (S, hex 0x53, dec 83) - Target Speed
ActSpd (s, hex 0x73, dec 115) - Actual Speed
Link
Value:
Limit Speed
Range:
0 to 65,535 position units per second
These link types are used to detect when the speed of the current axis has reached a user-
specified value. This link type can be used to change speeds on-the-fly or trigger events on
another axis. The Link Value holds the Limit speed in position units per second. Either the Target
Speed or Actual Speed may be used to compare with the Limit speed.
Using with the Link Type and Link Value Dialog Box
1. Under Link Type Category, select Current Axis (Basic).
2. Under Link Type, select Speed.
3. Under Link Condition, select whether you wish to use Target or Actual Speed for the comparison.
4. Under Link Condition, enter the Limit speed in the Threshold box.
Using without the Link Type and Link Value Dialog Box
1. Select the Link Type:
Use 'S' to compare with the Target Speed, 's' to compare with the Actual Speed.
2. Enter the Limit speed in the Link Value.
E.5.5 Link Type - Current Axis Status Bits
Link
Type:
BitsON (B, hex 0x42, dec 66)
BitsOFF (b, hex 0x62, dec 98)
Link
Value:
Bit pattern that must be set or cleared
Range:
Any bits
These link types wait for at least one of a user-selectable group of Status Bits to be set or cleared
on the current axis.
Using with the Link Type and Link Value Dialog Box