Delta RMC101 User Manual Page 927

  • Download
  • Add to my manuals
  • Print
  • Page
    / 951
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 926
Appendix F: RMC100 Specifications
F-3
CE Tests Performed
See also General Wiring Information.
Radiated Emissions
EN55022 Class A
Conducted Emissions
EN55022 Class A
Electrostatic Discharge
EN61000-4-2 ±4 kV contact
EN50082-1 ±8 kV air
Radiated Immunity
EN61000-4-3 3 V/m
EN50082-1
ENV50204
Electrical Fast
Transient Burst
EN61000-4-4 1 kV (A/C)
EN50082-1 0.5 kV (I/O)
Conducted Immunity
EN61000-4-6 3 V rms
EN50082-1
UL, C-UL Specifics
See also General Wiring Information.
File Number
E141684
Input power 24VDC, 750 mA max.
All inputs and outputs must be
connected to Class 2 circuits only.
Failsafe Timers
No internal bus activity
After 15µs, the drive outputs are
disabled.
Software watchdog
After 26ms, the module resets and drive
outputs are disabled if the
microprocessor does not retrigger the
onboard watchdog timer.
Flash Memory Storage
Retention Time
10 years at 150°C, 20 years at 125°C
Write/erase Cycles
100,000 minimum
Transducer Inputs and Drive Outputs
See the appropriate section(s):
MDT Specifications
Analog Transducer Specifications
Quadrature Specifications