Delta PG-35 Service Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
2-4
PRODUCT DATA SHEET
SM DELTA 1-E.2 GB
Model Indoor Unit DELTA 50 DCI
Model Outdoor Unit DCR 50 R410A
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Btu/hr 17060(4780-18770) 18080(5460-20130)
Capacity
(1)
kW 5.0(1.4-5.5) 5.3(1.6-5.9)
Power input
(1)
kW 1.56 1.55
EER (Cooling) or COP(Heating)
(1)
W/W 3.21 3.42
Energy efficiency class A B
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 7.0 6.9
Starting current A 10.5
Circuit breaker rating A 20
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1230/1100/900
Air flow
(2)
H/M/L m3/hr 720/620/480
External static pressure Min-Max Pa
0
Sound power level
(3)
H/M/L dB(A) 56/54/47
Sound pressure level
(4)
H/M/L dB(A) 44/41/34
Moisture removal l/hr 2
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 900x205x295
Weight kg
11
Package dimensions WxHxD mm 960x270x360
Packaged weight kg 14
Units per pallet units 24 units per pallet
INDOOR
Stacking height units 8 levels
Refrigerant control EEV
Compressor type, model Scroll, PANASONIC 5CS130XCC03
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 920
Air flow H/L m3/hr 2160
Sound power level H/L dB(A) 63
Sound pressure level
(4)
H/L dB(A) 53
Dimensions WxHxD mm 795x290x610
Weight kg 38
Package dimensions WxHxD mm 945x395x655
Packaged weight kg 41
Units per pallet Units 9 units per pallet
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 1.26kg/7.5m
Additional charge per 1 meter g/m No need
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 1/2"(12.7)
Max.tubing length m. Max.15
OUTDOOR
Connections between
units
Max.height difference m. Max. 10
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.4 Delta 50 / DCR 50 DCI R410A
CONTENT
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 77 78

Comments to this Manuals