5-13
PERFORMANCE DATA & PRESSURE CURVES
SM DELTA 1-E.2 GB
5.6 Pressure Curves
5.6.1 Model: Delta 22 DCI Cooling – Test Mode
Suction Pressure VS.Outdoor Temp.
600
700
800
900
1000
1100
1200
10 15 20 25 30 35 40 45
Outdoor DB Temperature [ºC]
Suction Pressure [kPa]
22/15 DB /WB
24/17 DB /WB
27/19 DB /WB
29/21 DB /WB
32/23 DB /WB
Discharge Pressure VS. Outdoor Temp.
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
10 15 20 25 30 35 40 45
Outdoor DB TemperatureC]
Discharge Pressure [kPa]
22/15 DB /WB
24/17 DB /WB
27/19 DB /WB
29/21 DB /WB
32/23 DB /WB