2-1
PRODUCT DATA SHEET
SM DELTA 1-E.2 GB
2.1 Delta 22 / DCR 22 DCI R410A
Model Indoor Unit DELTA 22 DCI
Model Outdoor Unit DCR 22 R410A
Installation Method of Pipe
Flared
Characteristics Units Cooling Heating
Capacity
(1)
Btu/hr 7500(4440-8870) 8530(4440-10580)
kW 2.2(1.3-2.6) 2.5(1.3-3.1)
Power input
(1)
kW 0.66 0.73
EER (Cooling) or COP(Heating)
(1)
W/W 3.33 3.42
Energy efficiency class A B
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 3.0 3.3
Starting current A 10.5
Circuit breaker rating A 10
INDOOR
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1100/950/800
Air flow
(2)
H/M/L m3/hr 400/350/300
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 49/46/43
Sound pressure level
(4)
H/M/L dB(A) 36/33/30
Moisture removal l/hr 1
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 680x250x185
Weight kg 7
Package dimensions WxHxD mm 740x265x320
Packaged weight kg 10
Units per pallet units 36 units per pallet
Stacking height units 9 levels
OUTDOOR
Refrigerant control EEV
Compressor type, model Rotary, Panasonic 5RS092XDJ01
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 770
Air flow H/L m3/hr 1400
Sound power level H/L dB(A) 64
Sound pressure level
(4)
H/L dB(A) 54
Dimensions WxHxD mm 760x245x545
Weight kg 35
Package dimensions WxHxD mm 880x310x610
Packaged weight kg 38
Units per pallet Units 12 units per pallet
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 0.7kg/7.5m
Additional charge per 1 meter g/m No need
Connections between
units
Liquid line In.(mm) 1/4”(6.35)
Suction line In.(mm) 3/8”(9.53)
Max.tubing length m. Max.15
Max.height difference m. Max. 10
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.