Delta PG-35 User Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 55
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
11-13
CONTROL SYSTEM
SM DELTAZ 1-E.0 GB
11.11.2 Outdoor Unit Controller
11.11.2.1 Hardware Jumpers
JP9 JUMPER LAYOUT
EEPROM Data (PIN 9) ODU3 (PIN 7) ODU2 (PIN 5) ODU1 (PIN 3) ODU0 (PIN 1)
GND (PIN 10) GND (PIN 8) GND (PIN 6) GND (PIN 4) GND (PIN 2)
ODU MODEL SELECTION
ODU3 ODU2 ODU1 ODU0 ODU Model Compressor Type
OFF OFF OFF OFF Reserved
OFF OFF OFF ON A (Single DCR 22- Use Capillary) Toshiba-DA89 (4 Poles)
OFF OFF ON OFF B (Single DCR 25- Use Capillary) Toshiba-DA89 (4 Poles)
OFF OFF ON ON C (Single DCR 35- Use Capillary) Toshiba- DA108 (4 Poles)
OFF ON OFF OFF D (Reserved)
OFF ON OFF ON E (Single DCR 22- Use EEV) Panasonic-5RS092 (6 Poles)
OFF ON ON OFF F (Single DCR 25- Use EEV) Panasonic-5RS092 (6 Poles)
OFF ON ON ON G (Single DCR 35- Use EEV) Panasonic-5RS102(6 Poles)
ON OFF OFF OFF H
ON OFF OFF ON I
ON OFF ON OFF J
ON OFF ON ON K
ON ON OFF OFF L
ON ON OFF ON M
ON ON ON OFF N
ON ON ON ON O
PCB JUMPER SETTING FOR J2 HEAD
RXD (PIN 2) TEST (PIN 4) GND (PIN 6)
VCC (PIN 1) N/C (PIN 3) TXD100 (PIN 5)
1. Connect PIN 4 and PIN 6 to enter Buit-in-Test.
2. RXD, TXD100, VCC is for MegaTools connection.
PCB JUMPER J1 HEADER
J1 header is used for program flash.
11.11.2.2 Software Jumpers
Property 0 1
EEPROM DATA (J1) Use ROM* Use EEPROM
* Default values (used in the ROM)
J1 – EEPROM/ROM setting
When J1 is 1, ODU will use model/general parameters from EEPROM. If EEPROM is invalid, ODU
will ignore J1 and use/copy the ROM pointed by the selected jumpers (will also set an according
fault).