Table 5. Recommended Wire Gauges and Fusing
Catalog
Number
Rated
Volts
Req. Circuit
Protection
(In Amps,
Fast-Blow Fuse)
Min. Gauge
90
°C Wire
(In Cross
Sectional mm
2
)
Rated
Volts
Min. Gauge
90°C Wire
(In Cross
Sectional mm
2
)
63-23-612-8
110-120
220-240
380-415
3
1.5
0,8
1,0
1,0
1,0
110/120
220/240
1,0
1,0
63-23-625-8
110-120
220-240
380-415
6
3
1
1,0
1,0
1,0
110/120
220/240
1,0
1,0
63-23-650-8
110-120
220-240
380-415
10
6
3
1,5
1,0
1,0
110/120
220/240
1,0
1,0
63-23-710-8
110-120
220-240
380-415
15
10
6
2,5
1,5
1,0
110/120
220/240
1,5
1,0
63-23-720-8
110-120
220-240
380-415
30
15
10
6,0
2,5
1,5
110/120
220/240
4,0
1,5
63-23-730-8
110-120
220-240
380-415
45
25
15
16,0
4,0
2,5
110/120
220/240
6,0
2,5
63-23-750-8
110-120
220-240
380-415
80
40
20
25,0
10,0
4,0
110/120
220/240
16,0
4,0
63-28-775-8
220-240
380-415
60
30
16,0
6,0
110/120
220/240
25,0
10,0
63-28-810-8
220-240
380-415
80
40
25,0
10,0
110/120
220/240
35,0
16,0
63-28-815-8
220-240
380-415
110
60
50,0
16,0
110/120
220/240
45,0
25,0