DELTA LTL2000 Retrometer 3
Getting started:
Turn the LTL2000 on by pressing <ON>
Hold <ON> pressed until LCD shows:
Calibrate instrument if necessary, see Calibration
Remove the base frame and place the instrument over the road marking.
Press <RL> button. Measurement will start instantly, duration app. 3 sec.
When finished the measured Rl value, the date/time and status prompt is displayed.
The Rl value, time and status are automatically transferred to the internal data log for later readout to the
serial communication port.
Press the <PRINT> key to print the measurement result.
Calibration:
Zero calibration.
Mount the instrument in the base frame. Make sure that the light trap is absolutely clean and that the
calibration unit is removed.
Press and hold <2'nd> and then press <ZERO>. Follow the shown instructions.
LCD shows the following text:
The instrument is now ready for the next step in the traceable- or control calibration procedure.
Traceable.
Open the hatch and place the reference calibration unit in the middle position as shown on the graphics
on the bottom plate (see Appendix C - figure 24) and close the hatch.
Press <CALIB> and then <ENTER> to start. Follow the shown instruction.
LCD Shows the following text:
Retrometer Ready
è
LTL2000 rev. n
Zero Reading Zero Reading Zero Ok Zero Ok
è è è
Enter to start Please Wait Zero: 0.11% Ready
Rl Normal Cal. Mount Normal Calibrating
è è
Enter to Start Enter when ready Please Wait
Rl Normal =146 Rl Normal =147 Calib Done
è è
Enter=OK = edit Enter when OK Remove Rl Normal