Series Temperature Controller
Instruction Sheet
Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE
to ensure proper operation. Keep this instruction sheet handy for quick reference.
Precaution
DANGER! Caution! Electric Shock!
DTE is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration.
The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for opening the
enclosure) in case danger and damage on the device may occur.
WARNING!
1. Prevent dust or metallic debris from falling into the device and cause malfunctions. DO NOT modify or uninstall the circuit board of DTE
without being permitted. DO NOT use empty terminals.
2. Keep away from high-voltage and high-frequency environment during the installation in case of interference. Prevent using the device in
premises which contain:
(a) dust or corrosive gas; (b) high humidity and high radiation; (c) shock and vibration.
3. The power has to be switched off when wiring or changing the temperature sensor.
4. When installing the circuit board of the accessory, please make sure the power of the main unit is switched off and insert the accessory
into the correct slot on the main unit.
5. Make sure to use compensation wire which matches the thermocouple or platinum resistance when extending or connecting the
thermocouple or platinum resistance.
6. Keep the wire as short as possible when wiring a sensor to the controller. Separate the power cable and load wire in order to prevent
interference and induced noise.
7. Make sure the power cables and signal device are installed correctly before switching on the power; otherwise serious damage may
occur.
8. DO NOT touch the terminal or repair the device when the power is on; otherwise an electric shock may occur.
9. Please wait for 1 minute after the power is switched off to allow the capacitor to discharge and DO NOT touch the internal wiring within
this period.
10. DO NOT touch the internal terminal when DTE is either switched on or off in case you may damage the circuit.
11. Please place DTE with other heating objects (e.g. power supply) within proper distance while installing DTE.
Ordering Information
Series name DTE: Delta E series temperature controller
1 Device type
1: main unit 2: accessory
2 3 - 4
0T: 4-channel TC
0P: 3-channel PT
0T: 4-channel TC
0V: 4 channels of voltage pulse output
0C: 4 channels of linear current output
0R: 4 channels of relay output
0L: 4 channels of linear voltage output
CT: 4 channels of current transformer sensors
DS: Display and setup module
0P: 3-channel PT
0D: 8-channel EVENT input
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Instruction Sheet

- 1 - Series Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTE series temperature controller. Please read this

Page 2 -  Panel Layout!

- 10 - INA INB Content Explanation CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 Read/write output 1 value Unit: 0.1 % H1070(H110E)H1071(H120E)H1072(

Page 3 -  Output

- 11 - Communication Parameter Setting Content 0 1 2 3 4 5 6 Baudrate 2,400bps 4,800bps 9,600bps 19,200bps 38,400bps 57,600bps 115,200bpsPa

Page 4 -  Alarm Output

- 12 - ASCII Mode Read Command Read Response Message Write Command Write Response Message Start word ’:’ Start word ’:’ Start word ’:’ Star

Page 5 -  CT (Current Transformer)

- 13 - How to Mount & DIN Rail Size Connect maximum 7 DTC2000 or DTC2001 controllers to DTE by using DIN rail.

Page 6 -  EVENT Input

- 2 - Specifications Power input 24 VDC, isolated switching power supply Voltage range 90 to 110% rated voltage Power consumption Max. 10 W + 3

Page 7 -  Delayed Alarm!

- 3 - Input The standard DTE main unit is attached with 4 channels of inputs. You can purchase additional DTE20T or DTE20P to expand the number of

Page 8 -  Hot Runner Control!

- 4 - Value = 0 Value = 1 Value = 2 Value = 3 OUT1, OUT2** Heating control Cooling control Proportional output Disable output SUB1, SUB2*

Page 9 -  RS-485 Communication

- 5 - LED Display PWR: On  DTE is powered. RUN: On  Any of the channel is executing. COM: Flashing  Communication in progress ERR: Indicating e

Page 10 - - 10

- 6 -INA + INB input: INA+INB CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 OUT1 control mode 10A8H 10A9H 10AAH 10ABH 10ACH 10ADH 10AEH 10AFH Ala

Page 11

- 7 - How to Operate 1. Enable the slope function: Write 1234H into the address 47F1H and then 0020H into address 4824H. bits in 4824H Bit7 Bit6

Page 12 -  RTU Mode

- 8 - Output Limits! Function!The output is limited between the maximum and minimum percentages.  How to Operate Set up relevant parameters usin

Page 13 - - 13

- 9 - If there is already a set value in 4824H and you would like to modify it, reset it to 0 before you set up a new value. 2. Set up relevant p