Delta 211 Series Specifications Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
DVP201/202/211LC-SL Load Cell Module Operation Manual
CR#1: Firmware version
[Description]
High byte: Number at the left side of the decimal point in a version number
Low byte: Number at the right side of the decimal point in a version number
Example: V1.01CR#=H’0101
CR#2: Eigenvalue
[Description]
The specifications for load cells vary from brand to brand. Users need to set an eigenvalue according to the
specification for the load cell used.
Eigenvalue
Specifications for the
eigenvalue in a load cell
Selection of an eigenvalue Setting value in CR#2
0mV/VEigenvalue1 mV/V 1m V/V H’0000
1mV/VEigenvalue2 mV/V 2m V/V H’0001 (Default setting)
2mV/VEigenvalue4 mV/V 4m V/V H’0002
4mV/VEigenvalue6 mV/V 6m V/V H’0003
6mV/VEigenvalue20 mV/V 20m V/V H’0004
20mV/VEigenvalue40 mV/V 40m V/V H’0005
40mV/VEigenvalue80 mV/V 80m V/V H’0006
Eigenvalue80 mV/V Not supported
CR#3: Reaction time for measurement
[Description]
Users can set the time which needs to elapse before a weight is sampled. The shorter the time set is, the
shorter the time it takes to filter weights. The weights measured are not in a stability range. If the time set is
the maximum time which can be set, the weights measure will be in a stability range.
Reaction time for measurement
Input value Description
Mode 0: H’0000 2.5 ms
Mode 1: H’0001 10 ms
Mode 2: H’0002 16 ms
Mode 3: H’0003 20 ms
Mode 4: H’0004 50ms (Default setting)
Mode 5: H’0005 60 ms
Mode 6: H’0006 100 ms
Mode 7: H’0007 200 ms
Mode 8: H’0008 400 ms
CR#6: Returning to zero/Subtracting a tare
[Description]
Users can use CR#6 to restore the weight measured to zero.
Input value Description
K1 Subtracting the tare measured by CH1
K2 Not subtracting the tare measured by CH1
K3 Restoring the weight measured by CH1 to zero
K4 Subtracting the tare measured by CH2
K5 Not subtracting the tare measured by CH2
K6 Restoring the weight measured by CH2 to zero
4-6
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 40 41