Chapter 4 Control Registers
CR#7: Displaying a gross weight/net weight
[Description]
Users can choose to display a gross weight or a net weight. The channel which is not used can be disabled.
Bit 15~bit 8 Bit 7~bit 0
CH2 CH1
K0: Displaying a gross weight
K1: Displaying a net weight
CR#8~11: Tare measured by CH1/CH2
[Description]
Tares are displayed in CR#8~CR#11. Users can write tares to CR#8~CR#11, or use CR#8~CR#11 to read
tares.
CR#12~15: Weight measured by CH1/CH2
[Description]
Weights are displayed in CR#12~CR#15.
CR#16~17: Number of weights measured by CH1 in a stability range
[Description]
Factory setting: K5
Setting range: K1~K500
Please refer to section 4.3.2 for more information.
CR#18~19: Stability range for CH1/CH2
[Description]
Factory setting: K10
Setting range: K1~K10,000
Please refer to section 4.3.2 for more information.
CR#25: Total number of points which need to be adjusted
[Description]
Factory setting: K2
Setting range: K2~K20
Users generally adjust two points, but they can adjust several points. The maximum number of points which
can be adjusted is 20.
CR#26: Adjustment command
[Description]
An adjustment command is stored in CR#26.
Command value Description of CR#26
K1~K20
K1: The command value is used when no
weight is measured by CH1.
K2~K20: The command values are used when
point 1~point 19 which are measured
by CH1 need to be adjusted.
K21~40
K21: The command value is used when no
weight is measured by CH2.
K22~K40: The command values are used when
point 1~point 19 which are measured
by CH2 need to be adjusted.
4-7