Chapter 4 Control Registers
4.3.3 Determining Zero
If an object is removed from the load cell used, bit 6/bit 11 in CR#51 will be set to 1, bit 5/bit 10 in CR#51 will be
set to 1, and users can perform the next control. (If a weight measured is in the zero range specified, bit 5/bit 10
in CR#51 will be set to 1.)
DVP202LC-SL
Ch1
CH2
Load cell
No object
Average weight
Zero weight
Zero range
Time
Relev
ant control registers
CR#48/CR#49: Range for determining whether a weight measured by CH1/CH2 is 0 grams
4.3.4 Filtering out Weights
There are two ways to filter out weights.
Filtering out the maximum/minimum weight measured: If there is a maximum weight or a minimum weight,
CR#45/CR#46 can be used to filter out the maximum weight or the minimum weight. If the value in
CR#45/CR#46 is bigger, more weights will be filtered out. Setting range: K0~K8
Averaging weights: The values read are averaged so that a steady value is obtained. There may be peak
values due to unavoidable external factors, and the average value obtained changes accordingly. The
maximum number of values which can be averaged are 100.