Delta 211 Series Specifications Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
Chapter 5 Making Adjustment
Step 7: Write H2 to CR#26.
Step 8: Make sure that the value displayed is correct, and make the adjustment retentive. Write H’5678 to
CR#41. Please see the WPLSoft program shown below.
5.3 Example 2
Example: Three points are adjusted.
A load cell module is used independently. The steps in making adjustment are as follows.
Step 1: Select 3 in the The Num. of Adjustment box. The weight of the first weight is 500 g. It corresponds to
500 lsb. The weight of the second weight is 1000 g. It corresponds to 1000 lsb. The weight of the third weight is
1500 g. It corresponds to 1500 lsb. Please see the figure below.