VFD-B Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-20
When Pr.03-05 is set to 0, the analog output voltage is directly proportional to the output
frequency of the AC drive. With Pr.03-06 set to 100%, the Maximum Output Frequency
(Pr.01-00) of the AC drive corresponds to +10VDC on the AFM output.
Similarly, if Pr.03-05 is set to 1, the analog output voltage is directly proportional to the
output current of the AC drive. With Pr.03-06 set to 100%, then 2.5 times the rated current
corresponds to +10VDC on the AFM output.
Note: Any type of voltmeter can be used. If the meter reads full scale at a voltage less than 10
volts, the parameter 03-06 should be set using the following formula:
Pr. 03-06 = ((meter full scale voltage)/10) x 100%
For Example: When using the meter with full scale of 5 volts, adjust Pr.03-06 to 50%. If
Pr.03-05 is set to 0, then 5Vdc will correspond to Maximum Output Frequency.
03 - 07
Digital Output Multiplying Factor
a
Factory Setting: 01
Settings 01 to 20 times Unit: 1
This parameter determines the multiplying factor for the AC drives digital output frequency
at the digital output terminals (DFM-DCM). The number of output pulses per second is
equal to the AC drive output frequency multiplied by Pr.03-07. (Pulse per second = actual
output frequency x Pr.03-07)
03 - 08
Terminal Count Value
a
Factory Setting: 00
Settings 00 to 65500 Unit: 1
The parameter determines the value of the internal counter. The internal counter can be
triggered by the external terminal TRG. Upon completion of counting, the specified output
terminal will be activated. (Pr.03-00, to Pr.03-03 set to 14).
When the display shows c5555, the drive has counted 5,555 times. If display shows
c5555., it means that real counter value is between 55,550 to 55,559.
03 - 09
Preliminary Count Value
a
Factory Setting: 00
Settings 00 to 65500 Unit: 1
When the counter value is counted up from “1” to the set value of this parameter, the
corresponding multi-function output terminal will be activated, when set to 15 (Preliminary
Count Value Setting). The corresponding multi-function output terminal will be deactivated
upon completion of Terminal Count Value Attained.