Page view 92
VFD-B Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-58
LRC CHK 0 ‘7’ ‘0’
CR ‘7’ END 1
END 0
LF
LRC CHK 1
LRC CHK 0
‘1’
CR
END 1
END 0
LF
RTU mode:
Command message:
Response message:
ADR 01H
ADR 01H
CMD 03H
CMD 03H
21H Starting data
address
02H
Number of data
(count by byte)
04H
00H 17H Number of data
(count by word)
02H
Content of register
2102H
70H
CRC CHK Low 6FH 00H
CRC CHK High F7H
Content of register
2103H
00H
CRC CHK Low FEH
CRC CHK High 5CH
(2) 06H: single write, write single data to register.
Example: writing data 6000(1770H) to register 0100H. AMD address is 01H.
ASCII mode:
Command message: Response message:
STX ‘:’ STX ‘:’
ADR 1 ‘0’ ADR 1 ‘0’
ADR 0 ‘1’ ADR 0 ‘1’
CMD 1 ‘0’ CMD 1 ‘0’
CMD 0 ‘6’ CMD 0 ‘6’
‘0’ ‘0’
‘1’ ‘1’
‘0’ ‘0’
Register adress
‘0’
Register address
‘0’
‘1’ ‘1’
‘7’ ‘7’
‘7’ ‘7’
Data content
‘0’
Data content
‘0’
LRC CHK 1 ‘7’ LRC CHK 1 ‘7’
LRC CHK 0 ‘1’ LRC CHK 0 ‘1’
END 1 CR END 1 CR
END 0 LF END 0 LF
RTU mode:
Page view 92