DELTA LTL-X Retrometer 15
Figure: 3. Measurement field with wet night accessories mounted.
The tower of the LTL-X contains the illuminating and observation system and the control
electronics. At the bottom of the tower an optical system, with mirror, directs a beam of light
toward the road surface through a dust-protection window. A polymer shielding covers the
measuring area for normal operation (see above).
The LTL-X is controlled by multiple microprocessors. It is operated with an extractable key-
board located at the top of the retrometer. It executes the measurement automatically by push
of a button and presents the result on a display. The result is automatically transferred to the
internal memory. The measurement, along with its corresponding time, date, and other data
can be printed using the built-in printer.
Optical principle
The optical system in the LTL-X is covered by a patent pending. A long life xenon lamp in
the top of the tower generates the light for the measurements. After a field stop the light is
collimated by a lens and deflected through a mirror toward the road.
The reflected light from the road uses the same mirror and lens. Between the lens and the pho-
to detector field aperture, stops define the observation area. The illumination field is inside in
the observation field. This is important to assure correct measurement on profiled markings.
V
spectral correction is achieved by use of advanced optical filters.