1100 Series
1103A-33TG1
Diesel Engine - ElectropaK
42 kWm at 1500 rpm
51 kWm at 1800 rpm
Compact, Efficient Power
1100 Series is the result of an intensive period of customer research that has
guided the development of the range.
The new 3.3 litre cylinder block ensures bore roundness is maintained under the
pressures of operation. It also ensures combustion and mechanical noise is
lowered.
A new cylinder head has re-established Perkins mastery of air control.
Quality by Design
Product design and Class A manufacturing improvements enhance product
reliability while maintaining Perkins legendary reputation for durability.
Cost Effective Power
Compact size and low noise.
Lower fuel consumption and oil use.
500 hour service intervals.
2 year warranty.
Product Support
Total worldwide service is provided through a network of 4,000 distributors and
dealers.
TIPSS - The Integrated Parts and Support System enables customers to specify
and order parts electronically as well as service engines with on-line guides and
service tools.
Building upon Perkins proven
reputation within the power generation
industry, the 1100 Series range of
ElectropaK engines now fit even closer
to customers needs.
In the world of power generation
success is only gained by providing
more for less. With the 1103A-33TG1
Perkins has engineered even higher
levels of reliability, yet lowered the cost
of ownership.
1100A units are designed for territories
that do not require compliance to EPA
or EU emissions legislation. These
units are able to meet TA luft legislation.
The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS5514/1
Derating may be required for conditions outside these; consult Perkins Engines Company Limited
Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. q) of 0.8
Fuel specification: BS 2869: Part 2 1998 Class A2 or DIN EN 590
Lubricating oil: 15W40 to API CG4
Rating Definitions
Prime power: Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours of operation.
Standby power: Variable load. Limited to 500 hours annual usage, up to 300 hours of which may be continuous running. No overload is permitted.
All information in this document is substantially correct at time of printing and may be altered subsequently Publication No.1781/01/06 Produced in England ©2006 Perkins Engines Company Limited
Engine speed Type of
Typical generator Engine power
(rev/min)
Operation
output
(net) Gross Net
kVA kWe kWm bhp kWm bhp
1500 Prime power 45.0 36.0 42.2 56.6 41.3 55.4
Standby power 49.6 39.7 46.5 62.4 45.6 61.2
1800 Prime power 53.1 42.5 50.5 67.7 48.9 65.6
Standby power 58.7 46.9 55.6 74.6 53.9 72.3
Page view 5