SECTION 4 INSTALLATION
4-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 609741 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
The EMF assessment on this equipment was conducted at 0.5 meter.
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC)
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
! This equipment does not comply with IEC 61000312. If it is connected to a public low voltage system, it is the responsibility of
the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equip-
ment may be connected.
ce-emc 2 2010-10
4-2. Serial Number And Rating Label Location
The serial number and rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine
input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-3. Specifications
Model
Rated
Welding
Output
Voltage
Range
DC
Max
OCV DC
IP
Rating
Amperes Input at Rated Load Output, 50 or 60 Hz,
Three-Phase
200 V 230 V 380 V 400 V 440 V 460 V 575 V KVA KW
300
Amp
300 A @ 32
(29) Volts
DC, 100%
Duty Cycle
10 32 44 21M
48
3.7*
42
3.2*
27
1.8*
25
1.7*
23
1.6*
21
1.6*
17
1.3*
16.9
1.26*
12.9
0.21*
450
Amp
450 A @ 38
(36.5) Volts
DC, 100%
Duty Cycle
10 38 44 21M
72
3.2*
63
2.7*
39
2.6*
37
2.2*
33
2.1*
32
1.4*
25
1.1*
25.1
1.09*
21.1
0.26*
650
Amp
650 A @ 44
Volts DC,
100% Duty
Cycle
10 44 33 21M --
96
3.2*
58
3.3*
54
3.0*
50
2.8*
48
1.6*
38
1.3*
38.2
1.26*
34.2
0.35*
*While idling