60 Hz 3 Phase AC to Bulk DC Converter
(Inherent Harmonic Suppression)
MECHANICAL DIMENSIONS
MAIN OFFICE:
8203 Vineland Avenue, Sun Valley, CA 91352 (818) 504-0644 FAX: (818)768-0395
Visit our website at
www.abbott-tech.com and on-line quote form at [email protected].
AR 60
8203 Vineland Avenue
Sun Valley, CA 91352
Tel. 818-504-0644
Fax. 818-768-0395
Call us toll-free
1-800-367-8200
TYPE H - WATER-COOLED
Output Rack Mount
Power (W) Size A B C D E F G H J Space (REF)
2500 25 14.00 12.00 4.00 1.50 1.75 1.50 2.00 1.25 2.00 3U
3500 35 17.00 15.00 4.75 1.50 2.25 1.50 2.00 1.25 2.00 3U
5000 50 17.00 15.00 5.50 1.50 2.75 2.00 2.00 1.25 2.00 4U
7500 c o n s u l t f a c t o r y
10000 c o n s u l t f a c t o r y
P
J
M
Specifications are subject to change without notice
Last updated July 24, 2002
TYP
Output Rack Mount
Power (W) Size A B C E F G Space (REF)
1000 10 12.00 13.00 3.46 1.75 1.25 1.50 2U
1500 15 12.00 13.00 3.75 1.75 1.25 1.50 3U
2500 25 14.00 13.00 4.00 1.75 1.50 2.00 3U
3500 35 17.00 15.00 4.75 2.25 1.50 2.00 3U
5000 50 17.00 15.00 5.50 2.75 2.00 2.00 4U
TYPE A - FAN-COOLED
REGULATION:
ENVIRONMENT:
BATTERY CHARGER OPTION:
CONSTRUCTION:
Unregulated models:
- Load Regulation: 10% Typical
- Line Regulation: N/A
Regulated models:
- Load Regulation: 2% Typical
- Line Regulation: 2% Typical
Encapsulated to meet MIL-STD-810
for vibration,shock,acceleration,
sand, dust, humidity, saltspray,
fungus, sunshine, rain, explosion
and altitude.
To MIL-PRF-27, Grade 4,
Class S, steel case.
- Units that are used for charging
batteries can be supplied with
smart battery charger feature,
factory configurable to meet your
specific battery charging
requirements.
- Temperature compensation
available.
- Units are available with up to 4
state charge profile (lead acid).
BUILT-IN TEST:
Regulated models only.
- Input phase loss.
- Input under/over voltage.
- Remote Enable/Disable.
- Output under/over voltage.
- Output overload alarm.
- Over temperature condition.
- Fan locked rotor alarm.
K - UP TO 30A INPUT: .562: ABOVE 30A: .750
L - UP TO 150A: 5/16-18 STUD; ABOVE 150A: 3/18-16 STUD
M - 37
o
FLAIR x 3/8 316 STAINLESS FITTINGS
N - UP TO 30A INPUT: 8-32 SCREW; ABOVE 30A: 1/4-20 STUD
P - SEE MOUNTING PROVISIONS PAGE FOR SLIDE AND BRACKET INFORMATION
R - SEE MOUNTING PROVISIONS PAGE FOR RACK PANEL INFORMATION
P
L
N
E
12.00