INSTRUCTION MANUALPART NO. A08200 Rev. 0Copyright © 2004 Delta MachineryTo learn more about DELTA MACHINERY visit our website at: www.deltamachiner
10- ENGA08200GROUNDING INSTRUCTIONSRISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an esc
11- ENGA08200Voltage and Circuit ProtectionRefer to the Parts Manual for the voltage and minimum branch circuit requirements.Certain air compressors c
12- ENGA08200OPERATIONKnow Your Air CompressorREAD THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with you
13- ENGA08200Before Starting Break-in ProcedureSerious damage (for units with a tank) may result if the following break-in instructions are not close
14- ENGA08200MAINTENANCECustomer ResponsibilitiesDaily or after each useBefore each use Check Safety Valve ● Drain Tank
15- ENGA08200To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.2.
16- ENGA08200To Replace Regulator1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.2. Unplug outfi
17- ENGA08200Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal i
18- ENGA08200Regulator will not shut off air outlet.Damaged regulator. Replace.PROBLEMCAUSECORRECTIONIt is normal for "some" pressure drop t
19- ENGA08200PROBLEMCAUSECORRECTIONMotor will not run.Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse
2- ENGA08200SAFETY GUIDELINES - DEFINITIONSIndicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.I
20- ENGA08200A08200LIMITED WARRANTYDELTA MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defe
3- ENGA08200IMPORTANT SAFETY INSTRUCTIONSSave these instructionsImproper operation or maintenance of this product could result in serious injury and p
4- ENGA08200WARNING: Risk of BurstingAir Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion
5- ENGA08200WARNING: Risk to BreathingWARNING: Risk of Electrical ShockHAZARDHAZARDYour air compressor is powered by electricity. Like any other elect
6- ENGA08200WARNING: Risk of BurnsTouching exposed metal such as the compressor head or outlet tubes, can result in serious burns.Never touch any expo
7- ENGA08200Review and understand all instructions and warnings in this manual.Become familiar with the operation and controls of the air compressor.K
8- ENGA08200Model No. CP503Running Horsepower 1.5Bore 1-7/8"Stroke 1-1/4"Voltage/Hertz/ Phase 120/60/1Minimum Branch Circuit Requiremen
INSTALLATIONLocation of the Air CompressorLocate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at